Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the novalab domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /www/htdocs/w014f4d7/jora-friends-entwicklungsserver.de/labc/wp-includes/functions.php on line 6170

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the bold-builder domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /www/htdocs/w014f4d7/jora-friends-entwicklungsserver.de/labc/wp-includes/functions.php on line 6170

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the woocommerce domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /www/htdocs/w014f4d7/jora-friends-entwicklungsserver.de/labc/wp-includes/functions.php on line 6170

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the woocommerce-multilingual domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /www/htdocs/w014f4d7/jora-friends-entwicklungsserver.de/labc/wp-includes/functions.php on line 6170

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the responsive-lightbox domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /www/htdocs/w014f4d7/jora-friends-entwicklungsserver.de/labc/wp-includes/functions.php on line 6170

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the updraftplus domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /www/htdocs/w014f4d7/jora-friends-entwicklungsserver.de/labc/wp-includes/functions.php on line 6170

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the wordpress-seo domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /www/htdocs/w014f4d7/jora-friends-entwicklungsserver.de/labc/wp-includes/functions.php on line 6170

Warning: Cannot modify header information - headers already sent by (output started at /www/htdocs/w014f4d7/jora-friends-entwicklungsserver.de/labc/wp-includes/functions.php:6170) in /www/htdocs/w014f4d7/jora-friends-entwicklungsserver.de/labc/wp-includes/feed-rss2.php on line 8
Shop - LABC-Labortechnik https://jora-friends-entwicklungsserver.de/labc/en/shop-2/ Fri, 20 Jan 2023 13:45:31 +0000 en-US hourly 1 https://wordpress.org/?v=7.0 https://jora-friends-entwicklungsserver.de/labc/wp-content/uploads/2022/11/cropped-favicon-32x32.png Shop - LABC-Labortechnik https://jora-friends-entwicklungsserver.de/labc/en/shop-2/ 32 32 Qumat®-Q401 HR EPC https://jora-friends-entwicklungsserver.de/labc/en/product/qumat-q401-hr-epc/ Tue, 22 Nov 2022 07:41:22 +0000 https://jora-friends-entwicklungsserver.de/labc/product/qumat-q401-hr-epc/ Qumat®-Q401-HR

[ez-toc]

Protective gloves and other personal protective equipment are subject to continuous quality control. The quality of this equipment and its classification into different protection classes is regulated by standards. The relevant standards are DIN EN ISO 374, DIN EN ISO 16523, DIN EN ISO 6529 and F-739. The concentration of the chemical in relation to time are continuously recorded. As soon as the concentration exceeds a predefined value as a function of time, one speaks of a breakthrough. From this point on, the PPE no longer protects the user from the tested chemical. The breakthrough is defined according to the standard with a permeation rate > 1 µg min-1 cm-2.

Der Beitrag Qumat®-Q401 HR EPC erschien zuerst auf LABC-Labortechnik.

]]>
  • Resistance to chemicals is regulated in standard DIN EN ISO 374, DIN EN ISO 16523, DIN EN ISO 6529 and F-739
  • LABC-Permeation cells are manufactured according standard DIN EN ISO 374, DIN EN ISO 16523, DIN EN ISO 6529 and F-739
  • For testing with 23°C+-1 according the standards. Tests up to 35°C are possible
  • Economical use of permeation chemicals, as LABC-Permeation cells are used in an upright position. Approx. 10ml of liquid is required per permeation measurement
  • Gaseous permeation chemicals can also be measured with a separate adapter
  • Our permeation products are used worldwide
  • LABC-Permeation cells and permeation testers are exclusively manufactured in Germany
  • The permeation tests required for each permeation chemical are listed in the normative annexes
  • LABC-Labortechnik has developed various products for permeation measurement in laboratories since 1988. Our range includes products for measurements in the collection medium water as well as in the gas flow. As detectors we offer FPD, FID, PID electrodes, as well as pH electrodes, conductivity electrodes and redox electrodes.

    Measuring devices in the gas flow

    Our Qumat and Permobil workstation measure in the gas flow with a detector. This means that the collection medium is a gas. Here you have the option of using air or nitrogen as the collection medium. The measurements in the gas flow are carried out in an open loop system.

    Workplaces with water as a collection medium

    The NW50liquid workstation and the NW50 liqui permeation cells are operated with water as the collection medium. The collection medium is a deionised water. The permeation measurements take place in a closed loop system.

    Qumat®-Q401-H

    The Qumat®-Q401-HR analyser is used to measure the permeation rate of chemical protective gloves and clothing. The analyser measures the breakthrough of test chemicals in three permeation measuring cells according to DIN EN 374, DIN EN 6529, EN 16523 or F-739. The glove tester Qumat®-Q401-HR is available in two versions and differentiates only by its detector. The Qumat®-Q401-HR can be supplied with FID or with FID and FPD. The overview of detectable chemicals provides information on which detector is suitable for your application.

    Gloves are clamped into the permeation measuring cells, filled on one side with the liquid test substance to be examined and continuously flown through from the other side with a gaseous collection medium. These three defined gas streams are analysed in sequence for the volatile detectable test substance. The results are documented in tabular form. In addition, the temperature and airflow are recorded for each measurement.

    If a test substance with a permeation rate > of 1 µg min-1 cm-2 passes through the test specimen, a breakthrough according to DIN EN 374-3 and EN 16523-1 is present.

    Features Qumat401 HR FID undFID/FPD

    Detector

    FID

    FID/FPD

    test substances containing hydrocarbons for P- and S-containing test substances
    Article number 170-0328968 170-0360517
    Permeation cell 3x permeation measuring cell NW50 3x permeation measuring cell NW50
    Measuring lines Up to three permeation measuring cells can be measured Up to three permeation measuring cells can be measured
    the zero gas, a reference gas (isobutane 100ppm),reference gas in a permeation cell the zero gas, a reference gas (THT or trimethyl phosphite),reference gas in a permeation cell
    Required gas Air, hydrogen, nitrogen optional Air, hydrogen, nitrogen optional
    Reference gas / Calibration gas isoButane 100ppm THT and trimethyl phosphite
    Measuring circuits Use of up to 3 measuring cells Use of up to 3 measuring cells
    Temperature range Temperatures of 23 °C ±1 °C or 33 °C ±1 °C, as well as user-defined temperature ranges Temperatures of 23 °C ±1 °C or 33 °C ±1 °C, as well as user-defined temperature ranges
    Temperature is saved Temperature is saved
    Gas flow Integrated flowmeter for flow measurement with each measuring cycle Integrated flowmeter for flow measurement with each measuring cycle
    Software Evaluation programme that generates Excel-compatible data. Evaluation programme that generates Excel-compatible data.
    System requirements: PC with USB and Windows 7 or higher. System requirements: PC with USB and Windows 7 or higher.

    Permeation cell NW50

    Designed for liquid or gaseous test chemicals and gaseous collection media. Permeation cell NW50 according to EN 16523-1 (replaces EN374-3) for testing PPE films such as protective gloves or protective clothing to measure the permeability of the test substances for the samples.

    The permeation cell parts are held upright by a tripod without support. The PTFE holder for gloves < 0.5 mm is placed in between. Made by German glassblowers according to the standards.

    Der Beitrag Qumat®-Q401 HR EPC erschien zuerst auf LABC-Labortechnik.

    ]]>
    Qumat®-Q401 https://jora-friends-entwicklungsserver.de/labc/en/product/permeation-products-en/ Mon, 21 Nov 2022 11:16:40 +0000 https://jora-friends-entwicklungsserver.de/labc/?post_type=product&p=6098 Qumat®-Q401-HR

    [ez-toc]

    Protective gloves and other personal protective equipment are subjected to permanent quality control. The quality of this equipment and its classification into different protection classes is defined by standards.  The concentration of the chemical and the elapsed time are recorded regularly. As soon as the concentration exceeds a predefined value as a function of time, this is called a breakthrough. From this point on, the PPE no longer protects the user from the chemical. The breakthrough is defined with a permeation rate > 1 µg min-1 cm-2 according the standard.

    Der Beitrag Qumat®-Q401 erschien zuerst auf LABC-Labortechnik.

    ]]>
    Keyfacts of our permeation testers

     

    • Resistance to chemicals is regulated in standard 1186, 16523, 6529 and F-739
    • LABC-Permeation celles are manufactured according standard 1186, 16523, 6529 and F-739
    • For testing with 23°C+-1 according the standards. Tests upto 35°C are possible
    • In a world wide use
    • Developed and produced under quality controlled conditions in Germany
    • The permeation testers requiered for each permeation chemical are listed in normative Annexes

    Over the past 30 years, LABC-Labortechnik has developed various products for measuring permeation in laboratories. Our range includes products for measurements in the collecting fluid water as well as in the collecting inert gas. As detectors, we offer FDP, FID, PID electrodes, as well as pH electrodes, conductivity electrodes and redox electrodes.

     

     

    Inert gas testers

    Our Qumat and our Permobil working stations are testing with inert gas. This means that the collection medium is a gas. There you have to option to use air or nitrogen. The inert gas testers are measuring in a open loop system.

    Fluit water

    The NW50liquid working station and the NW50 liqui cells are operation with fluit water. The collection medium is a deionized water. The fluit water testing systems are measuring in a closed loop system.

     

     

    Qumat®-Q401-H

    The Qumat®-Q401-HR analyser is used to measure the permeation rate of chemical protective gloves and clothing. The analyser measures the breakthrough of test chemicals in three permeation measuring cells according to DIN EN 374, DIN EN 6529 and EN 16523. The glove tester Qumat®-Q401-HR is available in two versions and differs only in its detector. The Qumat®-Q401-HR can be supplied with FID or with FID and FPD. The overview of the detectable chemicals provides information on which detoctor is suitable for your application.

     

    Qumat 401 HR section Test samples are clamped into the permeation measuring cells, filled on one side with the liquid test substance to be examined and continuously flown through from the other side with a gaseous collection medium. These three defined gas flows are now analysed one after the other for the volatile detectable test substance. The results are documented in tabular form. In addition, the temperature and the air flow are recorded for each measurement.

     

    If a test substance passes through the test specimen with a permeation rate > 1 µg min-1 cm-2, a breakthrough is present according to DIN EN 374-3 and EN 16523-1.

     

    Features Qumat401 HR FID and FID/FPD

     

    Detektor FID FID/FPD
    kohlenwasserstoffhaltige Prüfsubstanzen für  P- und S-haltigen Prüfsubstanzen
    Artikelnummer 170-0328968 170-0360517
    Permeationszelle 3x Permeation cell NW50 3x Permeation cell NW50
    Messlinien bis zu drei Permeationsmesszellen aus Glas bis zu drei Permeationsmesszellen aus Glas
    das Nullgas, ein Referenzgas (Isobutan 100ppm),Referenzgas in einer Permeationszelle das Nullgas, ein Referenzgas (THT oder Trimethylphosphit),Referenzgas in einer Permeationszelle
    benötigte Gas Luft, Wasserstoff, Stickstoff optinal Luft, Wasserstoff, Stickstoff optinal
    Referenzgas / Kalibriergas isobutan 100ppm THT und Trimethylphosphit
    Messkreise Nutzung von bis zu 3 Messzellen Nutzung von bis zu 3 Messzellen
    Temperaturbereich Temperaturen von 23 °C ±1 °C oder 33 °C ±1 °C, sowie benutzerdefinierte Temperaturbereiche Temperaturen von 23 °C ±1 °C oder 33 °C ±1 °C, sowie benutzerdefinierte Temperaturbereiche
    Temperatur wird gespeichert Temperatur wird gespeichert
    Gasdurchfluss Integriertes Flowmeter zur Durchfussmessung bei jedem Messzyklus Integriertes Flowmeter zur Durchfussmessung bei jedem Messzyklus
    Software Auswertungsprogramm, das Excel-kompatible Daten erzeugt. Auswertungsprogramm, das Excel-kompatible Daten erzeugt.
    Voraussetzung: PC mit USB und Windows 7 oder höhe Voraussetzung: PC mit USB und Windows 7 oder höhe

     

     

    Permeatin cell NW50

    Designed for liquid or gaseous test chemicals and gaseous collection media. Permeation cell NW50 in accordance to EN 16523-1 (replaces EN374-3) for testing PPE films such as safety gloves or safety clothing in order to measure the permeability of the test substances to the samples.

    Device made of glass and standing without support on three feet and a PTFE holder for films < 0.5 mm.
    Manufactured by German glassblowers.

     

    Der Beitrag Qumat®-Q401 erschien zuerst auf LABC-Labortechnik.

    ]]>
    Sieg-Mi-Flex migration cell system with individual serial number https://jora-friends-entwicklungsserver.de/labc/en/product/sieg-mi-flex-migration-cell-system-with-individual-serial-number/ Wed, 02 Nov 2022 19:04:23 +0000 https://jora-friends-entwicklungsserver.de/labc/produkt/sieg-mi-flex-migration-cell-system-with-individual-serial-number/ Individual serial number

    Sieg-Mi-Flex stainless steel migration cells are now available with individual serial numbers and a factory certificate for individual proof of dimensional accuracy. Stainless steel migration cells of LABC-Labortechnik are produced in highest quality according to EN DIN ISO 2768-1. All stainless steel center rings and fixing plates are marked with individual batch numbers. An individual factory certificate is supplied for each product on request. In this way, we increase the possibilities for traceability. This is unique in the world for migration cells.

    Der Beitrag Sieg-Mi-Flex migration cell system with individual serial number erschien zuerst auf LABC-Labortechnik.

    ]]>
    Der Beitrag Sieg-Mi-Flex migration cell system with individual serial number erschien zuerst auf LABC-Labortechnik.

    ]]>
    Sieg-Mi-Flex Migration Cell System https://jora-friends-entwicklungsserver.de/labc/en/product/sieg-mi-flex-migration-cell-system/ Mon, 10 Sep 2018 12:36:25 +0000 https://jora-friends-entwicklungsserver.de/labc/produkt/sieg-mi-flex-migration-cell-system/ Victory Mi-Flex

    [ez-toc]

    Der Beitrag Sieg-Mi-Flex Migration Cell System erschien zuerst auf LABC-Labortechnik.

    ]]>
    Sample preparation with the modular and flexible Sieg-Mi-Flex migration cell for analytical measurement and organoleptic testing of migration of packaging ingredients, “extractables and leachables” (E&L) and MOSH/MOAH in food simulants, in headspace or in pharmaceutical formulations for regulatory compliance.

     

     

    Advantages of the Sieg-Mi-Flex

     

    • Sieg-Mi-Flex is available in the materials: Stainless steel (VA 1.4571), borosilicate glass and PFA-coated stainless steel.
    • They can be combined with each other.
    • with individual serial numbers and a factory certificate for individual proof of dimensional accuracy
    • All center rings and all reduction plates of the Sieg-Mi-Flex system fit into the fixation plate set of the migration cell system Sieg-Mi-Flex with the size 140 x 140 mm (EN1186-1:2002) for the examination of different sized sample areas at defined surface/volume ratios.
    • Temperature resistant -15 °C to 180 °C, pressure-tight up to 9 bar (depending on material)

    • Is the most sold migration chamber
    • Rapid adaptation to special specimen sizes can also be achieved with the so-called reduction plates made of stainless steel (VA 1.4571) in conjunction with the center rings.
    • The Sieg-Mi-Flex can also be equipped with 2 packaging patterns (top/bottom).
    • The migration cell is then stored upright instead of lying horizontally.
    • The barrier effect of packaging materials can also be tested, e.g. with the “sandwich arrangement” test setup.
    • Sieg-Mi-Flex are issued individually with a batch number, so a works certificate can be issued for each center ring and fixing plate.

     

    With the help of the Sieg-Mi-Flex migration cells, a migration assessment of packaging ingredients from food repackaging can already take place on the finished roll goods.
    Tests have shown that temperature equilibration by diffusion is sufficient when the migration cell filled with a simulant remains upright for 24 h.
    There is no need to turn around. The migration cell is easy to close or open with stainless steel knurled screws. Their compact, space-saving design can be stored horizontally or vertically for temperature control in drying ovens or bath/circulating circulators.

    In the Sieg-Mi-Flex migration cell system, many sizes and thicknesses of packaging in a wide variety of material compositions can be tested with all liquid and solid food simulants.
    For studies with solid food simulants (E) poly-2,6-diphenyl-p-phenylene oxide (MPPO), the Tenax kit is used. Some customers also use the Tenax kit for migration testing with oil, as the fixing plate with the GL45 spout is easier to clean in the dishwasher than the center rings with the GL14 pour-in and GL14 pour-out spouts.
    The Sieg-Mi-Flex MIgration cell is then subjected to the test conditions with one test piece lying horizontally at a time. Due to the high temperature resistance (-20 °C to 180 °C) and the high pressure tightness up to 9 bar, stainless steel migration cells System-Siegwerk (Sieg-Mi-Flex) can also be used for liquid food simulants under test conditions beyond their boiling point.

     

     

    Application examples

     

    Migration cells of the Sieg-Mi-Flex type are basically suitable for migration tests, among others according to EN1186. Migration tests can be performed with cloths, papers, foil or cardboard packaging, gloves and many other materials or surfaces.

    The following simulants can be used in the migration cell “Sieg-Mi-Flex”:

    (A) Ethanol 10 % vol
    (B) Acetic acid 3 % wt.
    (C) Ethanol 20 % vol.
    (D1) Ethanol 50 %Vol.
    (D2) vegetable oil with specific fatty acid distribution from VO EU 10/2011 (PIM)

    Also, according to EN1186 and Directive 97/48/EC, substitute simulants such as the solvents isooctane and ethanol 95 % vol. can be used, as well as other alternative simulants that do not chemically attack the materials stainless steel (V4A 1.4571), PTFE and FEP (tetrafluoroethylene-hexafluoropropylene copolymer).

     

     

    More information

     

    Cleaning migration cells

     

    The Sieg-Mi-Flex cells are completely disassembled for cleaning and left for approx. 15 min. sonicated with isopropanol at room temperature in an ultrasonic bath, then dried. Then rinsed with ethanol pure LC-MS quality and dried again.

    The individual parts of the Sieg-Mi-Flex migration cell are dishwasher safe

     

    Food categories and simulants in Regulation 10/2011 (PIM)

     

    Food properties: Simulant food:
    Hydrophilic (A) Ethanol 10 % vol.
    Hydrophilic; < pH 4.5 (B) Acetic acid 3% wt.
    Hydrophilic/lipophilic; alcohol content up to 20%. (C) Ethanol 20 % vol.
    Lipophilic; alcohol content >20 %; O/W emulsion (D1) Ethanol 50 % vol.
    Lipophilic; free fats (D2) Vegetable oil with specific fatty acid distribution
    Dry food (E) Poly-2,6-diphenyl-p-phenylene oxide (MPPO)

     

    Due to the flexibility and modular design of the System-Siegwerk (Sieg-Mi-Flex) migration cell system, many sizes and thicknesses of packaging of different material compositions can be used for migration testing with all liquid and solid food simulants, food simulants for substitute testing (isooctane, ethanol 95 vol.%) or solvents from pharmaceutical formulations even beyond their boiling point on a defined sample area and with subsequent storage depending on time and temperature. The migration cell system Siegwerk (Sieg-Mi-Flex) following EN 1186-1:2002 (D), Annex C (informative), Figure C.4-Cell Type B and Figure C.5-Cell Type C, was developed and tested in cooperation with the analytical department of Siegwerk Druckfarben AG & Co. KGaA.

     

     

     

    An overview of all versions of our Sieg-Mi-Flex migration cell and matching accessories:

    Der Beitrag Sieg-Mi-Flex Migration Cell System erschien zuerst auf LABC-Labortechnik.

    ]]>